Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.085
Filtrar
1.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38635765

RESUMO

CASE: We present 2 cases of severe hemodynamic collapse during prophylactic stabilization of impending pathologic humerus fractures using a photodynamic bone stabilization device. Both events occurred when the monomer was infused under pressure into a balloon catheter. CONCLUSION: We suspect that an increase in intramedullary pressure during balloon expansion may cause adverse systemic effects similar to fat embolism or bone cement implantation syndrome. Appropriate communication with the anesthesia team, invasive hemodynamic monitoring, and prophylactic vent hole creation may help mitigate or manage these adverse systemic effects.


Assuntos
Embolia Gordurosa , Fraturas Espontâneas , Doenças Vasculares , Humanos , Fraturas Espontâneas/etiologia , Úmero/cirurgia , Úmero/patologia , Embolia Gordurosa/etiologia , Próteses e Implantes/efeitos adversos
2.
Angiol. (Barcelona) ; 76(2): 109-112, Mar-Abr. 2024. ilus
Artigo em Espanhol | IBECS | ID: ibc-232386

RESUMO

Introducción: la infección de prótesis aórtica en la cirugía vascular convencional es un evento catastrófico, con una alta tasa de morbilidad y de mortalidad. El tratamiento tradicional ha sido la remoción de la prótesis y la reconstrucción con bypass extraanatómico. En algunos casos, se ha llevado a cabo el reemplazo con prótesis impregnadas en antibiótico; en otros, el reemplazo con vena femoral superficial y también la cirugía abierta con drenaje de las colecciones asociadas y antibioticoterapia de por vida. Caso clínico: se presenta el reporte de un caso de infección protésica tratada con drenajes de las colecciones y antibioticoterapia de larga duración, con un resultado favorable un año después de su complicación. Discusión: en algunos casos, dada la severidad del paciente, es posible intentar un tratamiento conservador de esta nefasta complicación.(AU)


Introduction: in traditional vascular surgery, aortic prosthesis infection is a catastrophic event with high morbidity andmortality rates. Traditional treatment is the removal of the valve followed by extra-anatomic bypass reconstruction. Insome cases, antibiotic-impregnated prosthesis replacement has been performed. In others, superficial femoral veinreplacement, and open surgery with drainage of the associated collections and lifelong antibiotic therapy.Case report: this is the case of a patient with aortic prosthesis infection undergoing draining collections and lifelongantibiotic therapy with a favorable outcome 1 year after the complication.Discussion: in some cases, given the severity of the patient, we can try to treat this dreaded complication conservativel.(AU)


Assuntos
Humanos , Masculino , Idoso , Terapias Complementares , Próteses e Implantes/efeitos adversos , Infecções Relacionadas à Prótese/tratamento farmacológico
3.
Childs Nerv Syst ; 40(5): 1525-1531, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38329505

RESUMO

BACKGROUND: The ventriculoperitoneal shunt (VPS) is the gold-standard surgical technique to treat hypertensive hydrocephalus; however, it may fail in 20 to 70% of cases. The present study shows an alternative for patients with contraindications to VPS. METHODS: A case series of nine patients. The medical records of all patients under 17 years of age who underwent ventriculo-gallbladder (VGB) shunt at a pediatric hospital from January 2014 to October 2022 were reviewed. RESULTS: There were 6 (66.7%) males and 3 (33.3%) females. The average age of 73.6 months or 6.1 years at the time of surgery. They had undergone, on average, 5.1 VPS reviews before the VGB shunt. Five (55.5%) had complications of VGB shunt: infection (11.1%), atony (11.1%), hypodrainage (11.1%), and ventriculoenteric fistula (22.2%); all these patients got better at surgical reapproach, and in two of them, the VGB shunt was re-implanted. CONCLUSION: This case series shows a lower risk of death and a similar risk of complications compared to other alternative shunts. This article spotlighted VGB as a viable alternative when VPS fails or has contraindications.


Assuntos
Fístula , Hidrocefalia , Criança , Masculino , Feminino , Humanos , Vesícula Biliar/cirurgia , Derivação Ventriculoperitoneal/efeitos adversos , Hidrocefalia/cirurgia , Próteses e Implantes/efeitos adversos , Fístula/complicações , Fístula/cirurgia
4.
BMC Musculoskelet Disord ; 25(1): 115, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38331756

RESUMO

BACKGROUND: Instrumentation failure (IF) is a major complication associated with growth-sparing surgery for pediatric spinal deformities; however, studies focusing on IF following each surgical procedure are lacking. We aimed to evaluate the incidence, timing, and rates of unplanned return to the operating room (UPROR) associated with IF following each surgical procedure in growth-sparing surgeries using traditional growing rods (TGRs) and vertical expandable prosthetic titanium ribs (VEPTRs). METHODS: We reviewed 1,139 surgical procedures documented in a Japanese multicenter database from 2015 to 2017. Of these, 544 TGR and 455 VEPTR procedures were included for evaluation on a per-surgery basis. IF was defined as the occurrence of an implant-related complication requiring revision surgery. RESULTS: The surgery-based incidences of IF requiring revision surgery in the TGR and VEPTR groups were 4.3% and 4.0%, respectively, with no significant intergroup difference. Remarkably, there was a negative correlation between IF incidence per surgical procedure and the number of lengthening surgeries in both groups. In addition, rod breakage in the TGR group and anchor-related complications in the VEPTR group tended to occur relatively early in the treatment course. The surgery-based rates of UPROR due to IF in the TGR and VEPTR groups were 2.0% and 1.5%, respectively, showing no statistically significant difference. CONCLUSIONS: We found that IF, such as anchor related-complications and rod breakage, occurs more frequently earlier in the course of lengthening surgeries. This finding may help in patient counseling and highlights the importance of close postoperative follow-up to detect IF and improve outcomes.


Assuntos
Escoliose , Criança , Humanos , Escoliose/cirurgia , Escoliose/diagnóstico , Titânio , Próteses e Implantes/efeitos adversos , Costelas/cirurgia , Costelas/anormalidades , Reoperação , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Coluna Vertebral/anormalidades , Estudos Retrospectivos , Resultado do Tratamento , Estudos Multicêntricos como Assunto
5.
Eur J Orthop Surg Traumatol ; 34(3): 1581-1595, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38363346

RESUMO

PURPOSE: There is a lack of consensus regarding the best type of reconstruction of the proximal femur following bone tumor resection. The objective of this study was to analyze the complication risks, implant survival, and functional outcomes following modular prosthesis (MP) and allograft-prosthesis composite (APC) reconstruction of the proximal femur after primary bone tumor resections. METHODS: We performed a search in the PubMed and Scopus libraries, obtaining 1 843 studies. We included studies reporting functional outcomes, complications, and implant survival of proximal femur reconstruction with MP or APC following primary bone tumor resection with a 2-year minimum follow-up. We excluded studies analyzing metastatic patients or studies with pooled data in which it was impossible to separate the data of patients with primary bone tumors from those with bone metastases. RESULTS: We analyzed 18 studies (483 patients) reporting on 234 (48%) patients with MP reconstruction and 249 (52%) patients with APC reconstruction. The risk of complications was similar in patients with MP reconstruction (29%; 95% CI [0.11; 0.47]) and APC reconstruction (36%; 95% CI [0.24; 0.47]) (p = 0.48). Implant survival following MP reconstruction ranged from 81 to 86% at 5 years, 75 to 86% at 10 years, and 82% at 15 years. Implant survival following APC reconstruction ranged from 86 to 100% at 5 years and 86% at 10 years, and 86% at 15 years. Functional outcomes following MP reconstruction and APC reconstruction ranged from 24.0 to 28.3 and from 21.9 to 27.8, respectively. CONCLUSION: Patients with primary bone tumor of the proximal femur who underwent MP or APC reconstruction seem to have similar complication risks, implant survival, and functional outcomes.


Assuntos
Neoplasias Ósseas , Fêmur , Humanos , Resultado do Tratamento , Fêmur/cirurgia , Fêmur/patologia , Neoplasias Ósseas/patologia , Próteses e Implantes/efeitos adversos , Aloenxertos , Estudos Retrospectivos , Transplante Ósseo/efeitos adversos
9.
Artigo em Inglês | MEDLINE | ID: mdl-37820602

RESUMO

The most widely used laryngeal surgery technique for patients with vocal fold paralysis is medialization thyroplasty. Materials such as Gore-Tex, silastic, and hydroxyapatite are often used, and the most worrisome possible complication is extrusion of the implant. A 36-year-old female patient with a history of pediatric cardiac surgery was diagnosed with left vocal cord paralysis after an episode of upper respiratory infection with a working diagnosis of subclinical left vocal cord paralysis following cardiac surgery. She underwent medialization thyroplasty with a Gore-Tex implant under local anesthesia. On the 21st postoperative day, she presented with sudden-onset hoarseness and dysphagia due to Gore-Tex implant extrusion. The implant was removed and augmentation of the left vocal cord with adipose tissue was performed. Only 14 cases of Gore-Tex implant extrusion have been described in the literature so far. The aim of this case report was not only to show one possible complication when using a Gore-Tex implant but also to present fat augmentation as one of the solutions for revision medialization and salvage treatment, with sustained long-term results.


Assuntos
Laringoplastia , Paralisia das Pregas Vocais , Feminino , Humanos , Criança , Adulto , Paralisia das Pregas Vocais/etiologia , Paralisia das Pregas Vocais/cirurgia , Laringoplastia/efeitos adversos , Laringoplastia/métodos , Prega Vocal/cirurgia , Próteses e Implantes/efeitos adversos , Politetrafluoretileno
10.
J Fr Ophtalmol ; 47(3): 104023, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37973521

RESUMO

PURPOSE: To compare visual and glaucoma outcomes in patients with known glaucoma after a penetrating keratoplasty (PKP) or a Boston Keratoprosthesis Type 1 (KPro) as a second corneal replacement procedure. DESIGN: Retrospective interventional case series. PARTICIPANTS: Charts of 141 eyes that underwent either a PKP or KPro at the Centre hospitalier de l'Université de Montréal after one failed PKP from 2008 to 2020 were reviewed. Forty-six eyes with preoperative glaucoma were included. METHODS: Data collected included demographics, indication for the initial surgery, best corrected visual acuity (BCVA), concurrent ocular disorders, number of glaucoma medications, need for glaucoma surgery, cup-to-disc ratios (CDRs), mean RNFL thickness, and visual field (VF) characteristics. Primary outcomes were glaucoma progression trends. Secondary outcomes were visual outcomes and need for additional procedures. RESULTS: Mean follow-up was 4.7 years for the PKP and 7.3 for the KPro group (P<0.007). 30.6% of PKP compared to 70.5% of KPro patients were diagnosed with glaucoma preoperatively. Glaucoma worsened similarly in both groups; this is based on an analysis of the number of glaucoma medications, CDR, need for glaucoma surgery, and characteristic VF changes. Patients in the PKP group required significantly more regrafts than patients in the KPro group (31.8 vs. 8.3%; P=0.045). CONCLUSIONS: A preoperative diagnosis of glaucoma does not preclude KPro implantation. In glaucomatous eyes, the disease progressed similarly in both groups. Since both procedures increase the risk of worsening glaucoma, close follow-up is recommended. KPro may decrease the need for further corneal transplantation surgery.


Assuntos
Doenças da Córnea , Glaucoma , Humanos , Córnea/cirurgia , Ceratoplastia Penetrante/efeitos adversos , Estudos Retrospectivos , Próteses e Implantes/efeitos adversos , Doenças da Córnea/diagnóstico , Doenças da Córnea/epidemiologia , Doenças da Córnea/etiologia , Glaucoma/diagnóstico , Glaucoma/epidemiologia , Glaucoma/etiologia
11.
Mil Med ; 189(1-2): e443-e447, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-37534897

RESUMO

Traumatic aniridia from combat ocular trauma can cause visual disability. A 41-year-old male Army Veteran was referred for evaluation of light sensitivity and glare secondary to subtotal traumatic aniridia of his left eye from an improvised explosive device blast. A custom-made artificial iris prosthesis was implanted in the ciliary sulcus and secured using Gore-Tex sutures. After surgery, the patient reported improvement of his light sensitivity and quality of life. The custom iris prosthesis is a surgical option for visual disability resulting from traumatic aniridia from combat ocular trauma.


Assuntos
Aniridia , Traumatismos Oculares , Masculino , Humanos , Adulto , Implantação de Prótese/métodos , Iris/cirurgia , Iris/lesões , Aniridia/complicações , Aniridia/cirurgia , Fotofobia/complicações , Fotofobia/cirurgia , Qualidade de Vida , Traumatismos Oculares/complicações , Traumatismos Oculares/cirurgia , Próteses e Implantes/efeitos adversos
12.
Eur J Orthop Surg Traumatol ; 34(1): 251-269, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37439887

RESUMO

AIM: Polymers and metals, such as polyethylene (PE) and cobalt chrome (CoCr), are common materials used in thumb-based joint implants, also known as CMC (Carpometacarpal) arthroplasty. The purpose of this review was to investigate the reported failure modes related to wear debris from these type of materials in CMC implants. The impact of wear debris on clinical outcomes of CMC implants was also examined. Potential adverse wear conditions and inflammatory particle characteristics were also considered. METHOD: A literature search was performed using PRISMA guidelines and 55 studies were reviewed including 49 cohort studies and 6 case studies. Of the 55 studies, 38/55 (69%) focused on metal-on-polyethylene devices, followed by metal-on-metal (35%), and metal-on-bone (4%). RESULTS: The summarized data was used to determine the frequency of failure modes potentially related to wear debris from metals and/or polymers. The most commonly reported incidents potentially relating to debris were implant loosening (7.1%), osteolysis (1.2%) and metallosis (0.6%). Interestingly the reported mechanisms behind osteolysis and loosening greatly varied. Inflammatory reactions, while rare, were generally attributed to metallic debris from metal-on-metal devices. Mechanisms of adverse wear conditions included implant malpositioning, over-tensioning, high loading for active patients, third-body debris, and polyethylene wear-through. No specific examination of debris particle characterization was found, pointing to a gap in the literature. CONCLUSION: This review underscores the types of failure modes associated with wear debris in CMC implants. It was found that failure rates and adverse wear conditions of CMC implants of any design are low and the exact relationship between wear debris and implant incidences, such as osteolysis and loosening remains uncertain. The authors note that further research and specific characterization is required to understand the relationship between debris and implant failure.


Assuntos
Osteólise , Humanos , Osteólise/etiologia , Polegar/cirurgia , Próteses e Implantes/efeitos adversos , Polietileno , Artroplastia/efeitos adversos , Metais , Falha de Prótese
13.
J Vasc Surg Venous Lymphat Disord ; 12(1): 101676, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37696416

RESUMO

OBJECTIVE: Lymphedema is a chronic condition caused by impaired lymphatic fluid drainage, resulting in progressive edema. The current mainstay of lymphedema therapy consists of conservative therapy and surgical therapy. In this systematic review, we investigated the novel role of biomaterials in clinical lymphedema therapy and assessed their objective outcomes and the complication rate associated with their use. METHODS: Studies were identified through systematic review using the Embase and PubMed/MEDLINE databases. Only original articles reporting the use of biomaterials for clinical lymphedema therapy were included. The primary outcome measure was the objective reduction in limb volume after biomaterial use. The secondary outcome measure was the assessment of biomaterial safety. RESULTS: A total of 354 articles were identified in the first search, of which 10 met our inclusion criteria. These articles described the use of two biomaterials, nanofibrillar collagen scaffolds (NCSs) and silicone tubes (STs), for the treatment of lymphedema. NCS implantation showed an average excess limb volume reduction of 1% to 10.7% and clear evidence of lymphangiogenesis on imaging. No complications were 7documented after NCS implantation. ST implantation showed an average limb volume reduction of 700 to 887 mL and limb circumference reduction of 3.1 to 8 cm in patients with advanced stage lymphedema. Of 177 patients treated with ST implantation, only 11 (6.2%) developed local inflammation. CONCLUSIONS: Both NCS and ST implantation showed promising limb volume reduction; however, with the scarce literature available, additional research is needed to determine their effectiveness. Both demonstrated good safety profiles, with no complications after NCS implantation and a complication rate equivalent to other similar implants for ST implantation.


Assuntos
Materiais Biocompatíveis , Linfedema , Humanos , Linfedema/diagnóstico por imagem , Linfedema/etiologia , Linfedema/terapia , Edema , Extremidades , Próteses e Implantes/efeitos adversos
14.
J Orthop Res ; 42(1): 90-99, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37292040

RESUMO

The effect of long-term periprosthetic bone loss on the process of aseptic loosening of tibial total knee arthroplasty (TKA) is subject to debate. Contradicting studies can be found in literature, reporting either bone resorption or bone formation before failure of the tibial tray. The aim of the current study was to investigate the effects of bone resorption on failure of tibial TKA, by simulating clinical postoperative bone density changes in finite element analysis (FEA) models and FEA models were created of two tibiae representing cases with good and poor initial bone quality which were subjected to a walking configuration and subsequently to a traumatic stumbling load. Bone failure was simulated using a crushable foam model incorporating progressive yielding. Repetitive loading under a level walking load did not result in failure of the periprosthetic bone in neither the good nor poor bone quality tibia at the baseline bone densities. When applying a stumble load, a collapse of the tibial reconstruction was noticed in the poor bone quality model. Incorporating postoperative bone loss led to a significant increase of the failure risk, particularly for the poor bone quality model in which subsidence of the tibial component was substantial. Our results suggest bone loss can lead to an increased risk of a collapse of the tibial component, particularly in case of poor bone quality at the time of surgery. The study also examined the probability of medial or lateral subsidence of the implant and aimed to improve clinical implications. The FEA model simulated plastic deformation of the bone and implant subsidence, with further validation required via mechanical experiments.


Assuntos
Artroplastia do Joelho , Reabsorção Óssea , Prótese do Joelho , Fraturas da Tíbia , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Tíbia/cirurgia , Densidade Óssea , Próteses e Implantes/efeitos adversos , Fraturas da Tíbia/cirurgia , Reabsorção Óssea/etiologia , Prótese do Joelho/efeitos adversos
15.
Aesthet Surg J ; 44(3): 302-310, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-37551621

RESUMO

BACKGROUND: Over the past 4 decades, gluteal augmentation has increased enormously in popularity, and numerous techniques have been developed to provide patients with the best possible outcomes. The submuscular technique has been shown to be a reliable option for a broad cohort of patients. OBJECTIVES: The main objective of this retrospective study was to describe the characteristics and clinical outcomes of a group of patients who underwent gluteal augmentation by the submuscular technique. METHODS: A retrospective analysis was conducted on 80 female patients who underwent submuscular gluteal augmentation with silicone implants between August 2019 and May 2022. All of the patients were operated on by the authors of the present study. RESULTS: Information about patient demographics, implants, complications, and treatments was analyzed. Moreover, the satisfaction of the patients was assessed by means of a short survey. The most frequent complication was wound dehiscence. Only 7 patients required surgical revisions, and 2 required isolated antibiotic therapy. All complications were effectively addressed and no implants had to be removed. Furthermore, the retrospective analysis revealed a noteworthy association between the size of the implant and the occurrence of complications. CONCLUSIONS: The submuscular method provides the best aesthetic results and adequate safety for patients. It significantly minimizes the possibility of complications, such as fluid collection due to muscle fiber dissection or implant exposure/extrusion.


Assuntos
Implante Mamário , Implantes de Mama , Humanos , Feminino , Estudos Retrospectivos , Géis de Silicone/efeitos adversos , Nádegas/cirurgia , Próteses e Implantes/efeitos adversos , Implante Mamário/efeitos adversos , Implantes de Mama/efeitos adversos
16.
Oper Orthop Traumatol ; 36(1): 12-20, 2024 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-37812237

RESUMO

OBJECTIVE: Early onset scoliosis is defined as a spinal deformity originating in the first 10 years of life. Growth-preserving spinal instrumentation has therefore been designed to preserve growth of spine and chest wall and lungs to avoid serious pulmonary complications after early spine fusion. Indications, surgical technique and results of the vertical expandable prosthetic titanium rib (VEPTR) technique, traditional growing rods (TGR), and magnetically controlled growing rods (MCGR) will be described. INDICATIONS: Indications for VEPTR are so-called mixed congenital deformities (type 3) associated with vertebral malformations in association with chest wall deformities, especially fused ribs. There are also indications for neuromuscular or syndromic early onset scoliosis with bilateral rib-to-ilium constructs. However, most of those deformities are currently treated with either GR or MCGR in most centers. GR and MCGR are currently the treatment of choice for the majority of early onset scoliosis. CONTRAINDICATIONS: There is no indication for growth-preserving strategies if the patients are mature or there is only little growth remaining. In these cases, final fusion should be performed. SURGICAL TECHNIQUE: While the VEPTR technique involves an extensive approach with muscular dissections to the thoracic cage including rib osteotomies and thoracotomies, treatment with TGR or MCGR is minimally invasive, only exposing proximal and distal anchor points, leaving most of the spine including the apex undisturbed. POSTOPERATIVE MANAGEMENT: Early mobilization is usually possible after 24-48 h. Braces may have to be prescribed for patients with osteopenia, noncompliance, or a risk to fall. RESULTS: Since 2005, more than 200 patients were treated with the VEPTR technique, more than 200 patients with the MCGR technique, and about 30 patients with the TGR technique in our department. Complication rates are high with all techniques including the law of diminishing returns, autofusion, bone anchor-related complications like loosening or migration of implants, failure to distract and proximal junctional kyphosis. In our own series of 13 patients below age 3 years, VEPTR proved to be effective for mixed deformities. In other studies, we were able to show that physiological growth with MCGR can be maintained for 2-3 years but spinal growth declines after that period with acceptable complications. Complication rates in most studies are lower with MCGR compared to TGR and VEPTR. Therefore, it is currently the treatment of choice for most early onset scoliosis patients.


Assuntos
Escoliose , Humanos , Pré-Escolar , Escoliose/diagnóstico , Escoliose/cirurgia , Resultado do Tratamento , Coluna Vertebral/anormalidades , Coluna Vertebral/cirurgia , Próteses e Implantes/efeitos adversos , Titânio , Osteotomia , Estudos Retrospectivos
17.
Int J Cardiol ; 397: 131640, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38065326

RESUMO

BACKGROUND: The residual device patency (RDP) after left atrial appendage closure (LAAC) with the LACbes device has not been specifically explored in atrial fibrillation (AF) patients. This study aims to explore the incidence, impact and predictors of RDP detected by cardiac computed tomography angiography (CCTA) post LAAC. METHODS: AF patients implanted with the LACbes device were prospectively enrolled. CCTA device surveillance was performed at 3 months post-procedure. Major adverse events (MAEs), including stroke/transient ischemic attack, major bleeding and all-cause death, were evaluated. RESULTS: Among 141 patients with CCTA surveillance, 56 (39.7%) showed no visible leak and 85 (60.3%) showed RDP. During the median follow-up of 443 [232, 706] days, the presence of RDP was not associated with an increased risk of MAEs (adjusted hazard ratio [HR]: 4.07, 95% confidence interval [CI]: 0.49-34.24, p = 0.196), while peri-device leak (PDL) at the lobe was associated with heightened risks of MAEs (adjusted HR: 6.85, 95% CI: 1.62-28.89, p = 0.009). In patients with PDL at the lobe, antiplatelet after 6 months (HR: 0.20, 95% CI: 0.05-0.91, p = 0.038) was independent protective predictor of MAEs. Besides, current smoking (odds ratio [OR]: 7.52, 95% CI: 2.68-21.08, p < 0.001) and maximum diameter of LAA orifice (OR: 1.16, 95% CI: 1.00-1.34, p = 0.048) were independent predictors of PDL at the lobe. CONCLUSIONS: Presence of PDL at the device lobe detected by CCTA at 3-month post LAAC with LACbes is associated with unfavorable prognosis in AF patients. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03788941.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Incidência , Próteses e Implantes/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento
18.
Jt Dis Relat Surg ; 35(1): 231-241, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38108185

RESUMO

OBJECTIVES: This study overviewed the current database of studies on periprosthetic joint infections (PJIs) to compare outcomes and antibiotic side effects in culture-negative or culture-positive PJIs and assess treatment options for culture-negative PJIs. PATIENTS AND METHODS: A systematic review and meta-analysis was undertaken using studies published before July 2022 in MEDLINE, EMBASE, and Cochrane Library. All studies comparing treatment of culture-negative or -positive PJIs were included. Afterward, the infection control rate, periprosthetic or spacer fracture, hip joint or spacer dislocation, and antibiotic side effects in different treatment methods of PJI were analyzed. RESULTS: Eleven studies involving 1,747 patients were included. Most studies clearly defined the infection control criteria: no pain or swelling, no wound drainage, normal serology, and normal radiographic findings. Patients were followed until treatment failure, death, or until the last clinical visit without evidence of treatment failure. The two types of PJIs did not differ significantly in infection control rates (culture-negative PJI 79.2% vs. culture-positive PJI 76.6%; odds ratio [OR]=1.20, 95% confidence interval [CI]: 0.84 to 1.70), either after all types of surgical treatment or after two-stage revision arthroplasty (OR=1.12, 95% CI: 0.72 to 1.75), single-stage revision arthroplasty (OR=0.51, 95% CI: 0.19 to 1.37), or debridement, antibiotics, and implant retention (OR=0.88, 95% CI: 0.50 to 1.54). Similarly, we did not find differences in periprosthetic or spacer fracture and hip joint or spacer dislocation. For culture-negative PJIs, the infection control rate was 85.2% after two-stage revision arthroplasty, 90.6% after single-stage revision arthroplasty, and 69.7% after debridement, antibiotics, and implant retention. Data pooled from three studies showed higher incidence of antibiotic side effects for culture-negative PJIs. CONCLUSION: The clinical outcomes of one-stage revision and two-stage revision are comparable. Therefore, both of them can be considered in surgical treatment for culture-negative PJIs. In addition, limited data showed a higher incidence of antibiotic side effects in culture-negative PJIs.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Antibacterianos/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Articulação do Quadril/cirurgia , Próteses e Implantes/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia
19.
Instr Course Lect ; 73: 861-878, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38090945

RESUMO

The management of periprosthetic fractures with unstable prosthetic implants is a challenging and commonly encountered problem. It is important to address the many current issues and controversies regarding the treatment of periprosthetic fractures with revision total joint arthroplasty. Key strategies to optimize surgical decision making around the use of arthroplasty and management of complications following these complex injuries will be addressed.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Fraturas do Fêmur , Fraturas Periprotéticas , Humanos , Artroplastia do Joelho/efeitos adversos , Fraturas do Fêmur/complicações , Fraturas do Fêmur/cirurgia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Próteses e Implantes/efeitos adversos , Reoperação/efeitos adversos
20.
J Immunol ; 212(4): 663-676, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38149920

RESUMO

Implanted medical devices, from artificial heart valves and arthroscopic joints to implantable sensors, often induce a foreign body response (FBR), a form of chronic inflammation resulting from the inflammatory reaction to a persistent foreign stimulus. The FBR is characterized by a subset of multinucleated giant cells (MGCs) formed by macrophage fusion, the foreign body giant cells (FBGCs), accompanied by inflammatory cytokines, matrix deposition, and eventually deleterious fibrotic implant encapsulation. Despite efforts to improve biocompatibility, implant-induced FBR persists, compromising the utility of devices and making efforts to control the FBR imperative for long-term function. Controlling macrophage fusion in FBGC formation presents a logical target to prevent implant failure, but the actual contribution of FBGCs to FBR-induced damage is controversial. CD13 is a molecular scaffold, and in vitro induction of CD13KO bone marrow progenitors generates many more MGCs than the wild type, suggesting that CD13 regulates macrophage fusion. In the mesh implant model of FBR, CD13KO mice produced significantly more peri-implant FBGCs with enhanced TGF-ß expression and increased collagen deposition versus the wild type. Prior to fusion, increased protrusion and microprotrusion formation accompanies hyperfusion in the absence of CD13. Expression of fusogenic proteins driving cell-cell fusion was aberrantly sustained at high levels in CD13KO MGCs, which we show is due to a novel CD13 function, to our knowledge, regulating ubiquitin/proteasomal protein degradation. We propose CD13 as a physiologic brake limiting aberrant macrophage fusion and the FBR, and it may be a novel therapeutic target to improve the success of implanted medical devices. Furthermore, our data directly implicate FBGCs in the detrimental fibrosis that characterizes the FBR.


Assuntos
Corpos Estranhos , Reação a Corpo Estranho , Camundongos , Animais , Reação a Corpo Estranho/induzido quimicamente , Reação a Corpo Estranho/metabolismo , Células Gigantes de Corpo Estranho/metabolismo , Inflamação/metabolismo , Corpos Estranhos/metabolismo , Próteses e Implantes/efeitos adversos , Ubiquitinação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...